71
XMEGA A [MANUAL]
8077I–AVR–11/2012
Figure 6-3.
Event routing network.
Eight multiplexers means that it is possible to route up to eight events at the same time. It is also possible to route one
event through several multiplexers.
Not all XMEGA devices contain all peripherals. This only means that a peripheral is not available for generating or using
events. The network configuration itself is compatible between all devices.
(48)
PORTA
PORTB
PORTC
PORTD
PORTE
PORTF
ADCA
ADCB
DACA
DACB
TCF0
TCF1
(6)
(4)
TCE0
TCE1
(6)
(4)
TCD0
TCD1
(6)
(4)
TCC0
TCC1
(6)
(4)
(8)
(10)
(36)
(4)
(8)
ACA
ACB
RTC
(8)
CH0MUX[7:0]
CH1MUX[7:0]
CH2MUX[7:0]
CH3MUX[7:0]
CH4MUX[7:0]
CH5MUX[7:0]
CH6MUX[7:0]
CH7MUX[7:0]
CH1CTRL[7:0]
CH0CTRL[7:0]
CH2CTRL[7:0]
CH3CTRL[7:0]
CH4CTRL[7:0]
CH5CTRL[7:0]
CH6CTRL[7:0]
CH7CTRL[7:0]
Event Channel 7
Event Channel 6
Event Channel 5
Event Channel 4
Event Channel 3
Event Channel 2
Event Channel 1
Event Channel 0
ClkPER
(16)
(2)
(3)